  • Digital Oscilloscopes DS-5500A,DS-5400 Series
Digital Oscilloscopes DS-5500A,DS-5400 Series
Iwatsu

DS-5500A Series

  • Frequency bandwidth 100 - 500MHz
  • Maximum Sampling Speed 2GS/s
  • Input Channel 4
  • Maximum Memory Length 1Mpts/ch
  • DS-5400A Series
  • Frequency bandwidth 100 - 200MHz
  • Maximum Sampling Speed 2GS/s (200MHz Type)
  • Maximum Sampling Speed 1GS/s(100MHz Type)
  • Input Channel 4
  • Maximum Memory Length 500kpts/ch
  •  Japan Quality


   Please click for more information.






DS-5554ADS-5552ADS-5534ADS-5532ADS-5524ADS-5522ADS-5514ADS-5512A
Frequency bandwidth(-3dB)500MHz350MHz200MHz100MHz
Rise time(Typical))750ps1ns1.75ns3.5ns
Input Channel42424242
Maximum Sampling Speed1GS/s(all CHs)/ 2GS/s(Channel combined)1GS/s
Equivalent Sampling Rate100GS/s
Peak detect resolution1ns
Averaging2 to 256 times
Maximum Memory Length1Mpts/ch(for all CHs)
Vertical Resolution8-bit
Input voltage range2mV/div - 10V/div(1MΩ), 2mV/div - 2V/div(50MΩ)2mV/div - 10V/div(1MΩ)
Offset voltage2mV/div - 50mV/div : ±1V
50.2mV/div - 500mV/div : ±10V
502mV/div - 10V/div : ±100V
DC gain accuracy±1.5% + (0.5% of fullscale)
Maximum Input Voltage±400Vpeak CAT I (1MΩ), 5Vrms (50Ω)±400Vpeak CAT I (1MΩ)
Band-limiting filterAnalog form : 100MHz,20MHz,2MHz,200kHzAnalog form : 20MHz,2MHz,200kHz
Digital form : Either of LPF/HPF/OFF is selected with each channel.
4 independent channels
Input couplingGND, DC 1MΩ, AC 1MΩ,DC50ΩGND, DC 1MΩ, AC 1MΩ
Input Impedance1MΩ±1% //16pF、 50Ω±1%1MΩ±1% //20pF
Probe senseAutomatic: 1:1、10:1、100:1、1000:1
Manual: 1:1、5:1、10:1、20:1、50:1、100:1、200:1、500:1、1000:1、2000:1
Timebase500ps/div ~ 50s/div1ns/div ~ 50s/div2ns/div ~ 50s/div5ns/div ~ 50s/div
Standard probeSS-101R (multi-channel)SS-0130R (multi-channel)
Roll mode50ms/div ~ 50s/div (100kS/s max)
Timebase (Clock) accuracy±10 ppm
Trigger function
Trigger typeEdge, Edge ALT, Edge OR, Pulse Count, Pulse Width, Period,Dropout, TV, OR, NOR, AND, NAND
TV mode /
Line number /
Field sequence
NTSC, PAL, Custom / upto 3,000 / 1, 2, 4 & 8 fields
Pulse Count Trigger1 to 9999 events
Pulse Width Trigger15ns to 50s
Period Trigger40ns to 50s
Dropout Trigger50ns to 50s
Pattern Trigger OR、NOR、AND、NAND
Trigger source /
Status / 
threshhold level setting
All channels / High, Low、 Don't Care / All channels set independently
Trigger SourceInput CHs, Line, EXT(+/-0.5V), EXT10(+/-5.0V)
Trigger Slope /Coupling+,- / AC, DC, HF Rej, LF Rej, Noise Rej
Display function
Display size/ resolution7.5inch color TFT-LCD with Touch screen / VGA(640*480pixels)
Display modeYT、XY、XY (Triggered)
Vector Display MethodInterpolation on sample points or Dots
Analog persistence modeMonochrome grayscale or Color Spectrum
Persistence time setting100ms, 200ms, 500ms, 1s, 2s, 5s, 10s & Infinite
Reference waveform memory5 waveforms
Panel setting memory5settings for Internal memory or USB memory
Parameter measurement, Cursor, Zoom, Calculation, Replay
rameter measurementMaximum, Minimum, Peak-Peak, RMS, Cycle RMS, Mean, Cycle Mean, Top, Base, Top-Base, +Overshoot, -Overshoot, Tr 20-80%, Tf 80- 20%, Tr 10-90%, Tf 90-10%, Freq., Period, +Pulse Count, -Pulse Count, +Pulse Width, -Pulse Width, Duty Cycle, Integral, Skew (+, -), Skew at level
Concurrent number of measurements /
statistics display
Four parameter maximum /Max (Maximum), Min (Minimum) ,Num (Number of the total waveforms)
Logging item, destinationTime and parameter measurement results (conditions A, B, C, D), 
Pass/Fail judgment results When recording: Pop-up window,
internal memory (up to 86400 entries), After recording: USB memory
Pass/FailJudgment mode: Select between Parameter judgment and Mask judgment, 
Judgment result: Save waveform (USB memory)/ Beep/ Pulse output (when equipped with DS-578 option)/ Logging, 
Page search function: Select any of Fail or Pass, you can search forward or backward
CursorTime, Amplitude, Time and Amplitude, Value at cursor
ZoomZoom key enable display at individual grid area
CalculationAddition, Subtraction, Multiplication, FFT(8k points maximum, RECTANGULAR, HANNING, FLATTOP)
Rescaling / Unit conversiona*x+b(x: input voltage at User defined a and b) / Volt, Ampere, Watt, degree and unit-less
ReplayAutomatic waveform recording upto 1,024waveforms, History Replayable
Counter6-digit
Interface (standard)USB 2.0(Host&Device), LAN(100Base-TX), GPIB(Factory option: DS-576)
AUX InterfaceAUX connector for External options
Waveform Data StorageUUSB memory for Binary, ASCII, Mathcad, Calculation(ASCII) & Calculation(Mathcad)
Hardcopy OutputOutput form front panel USB port to USB memory in TIFF, BMP & PNG format or Output to PictBridge Printers
Calibration signal outputSquare waveform at 1kHz, 3Vp-p
Power / power consumptionAC 90Vrms to 240Vrms, 47Hz to 63Hz, AC 90Vrms to 132Vrms, 380Hz to 420 Hz, 95VA max (60W max)
Dimensions (mm) / WeightApprox. 330W × 190H ×124D / Approx. 3.7kg
Environmental condition
Performance guarantee temperature+10℃ to + 35℃
Operation temperature and humidity / 
Altitude conditions
0deg. to +40˚C at 5 to 80%(RH<=30˚C) and 55%RH or less at 40˚C non-condensation /
2,000meter or lower
Accessory
Probe(multi-channel), Power cord, Front panel cover, CD-ROM(Instruction Manual, Remote Control Manual), User's Guide
Factory options
AUX IO CH1/CH2 output
DS-577
(factory option)
AUX IO1: Output of CH1 input signal with applied offset voltage, AUX IO2: Output of CH2 input signal with applied offset voltage
AUX IO CH1/TRIG output
DS-578
(factory option)
AUX IO1: Output of CH1 input signal with applied offset voltage,
AUX IO2: H-level pulse signal output occurs under the following conditions
・Output when triggered
・Output when Pass/Fail judgment result becomes Pass or Fail
GPIB Interface
DS-576
(factory option)
GPIB: IEEE488.2 (factory option)
2 ways optional for Probe Power supply
DS-579
Our active probe power supply (2 systems)

Write a review

Please login or register to review